PEPTIDE WHOLESALERS
CATALOG · BPC-157 · CERTIFICATES

BPC-157 Certificate of Analysis

2 batches of BPC-157, each tested by Kovera Labs for purity, identity, net content, endotoxin, sterility, and heavy metals. Every result below is copied from the laboratory’s certificate, at the precision it was issued.

BATCHES PUBLISHED2
PURITY RETURNED99.384%–99.446%
FILLS COVERED5 MG, 10 MG
LATEST CERTIFIED2026-08-04
FILLBATCHPURITYIDENTITYENDOTOXINSTERILITYCERTIFIED
5 MGBATCH-501499.384%BPC-157 · confirmedPassNo Growth2026-08-04
10 MGBATCH-1076599.446%BPC-157 · confirmedPassNo Growth2026-08-04

NOT YET PUBLISHED: 20 MG · The certificate for the batch you receive is supplied with your shipment.

BPC-157 5 MG · BATCH-5014

99.384% PURITY
PURITY
99.384% against a specification of > 98%
NET CONTENT
5.41 mg (fill 5 MG)
IDENTITY
BPC-157, confirmed by LC-MS
ENDOTOXIN
Pass · limit ≤ 0.5 EU/mL
STERILITY
No Growth
HEAVY METALS
Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
REPORT · ACCESS CODE
KVR-2026-DFBC79-S460 · AJ8QR71
CHROMATOGRAM · RP-HPLC · C18 · DAD @ 214 nm
HPLC chromatogram for BPC-157 5 MG, batch BATCH-5014

BPC-157 10 MG · BATCH-10765

99.446% PURITY
PURITY
99.446% against a specification of > 98%
NET CONTENT
11.06 mg (fill 10 MG)
IDENTITY
BPC-157, confirmed by LC-MS
ENDOTOXIN
Pass · limit ≤ 0.5 EU/mL
STERILITY
No Growth
HEAVY METALS
Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
REPORT · ACCESS CODE
KVR-2026-BB76EF-S461 · 2M3Q0I2
CHROMATOGRAM · RP-HPLC · C18 · DAD @ 214 nm
HPLC chromatogram for BPC-157 10 MG, batch BATCH-10765

Reading a BPC-157 certificate

Purity is measured by reverse-phase HPLC on a C18 column with detection at 214 nm — the trace shown under each batch above. The figure is the share of the signal in the BPC-157 peak, and it is reported against the specification printed beside it.

Identity is confirmed separately by LC-MS, which checks the mass of what is in the vial against what is expected for BPC-157. Purity without identity would say how clean the sample is, not what it is.

Net content is the measured quantity in the vial against its stated fill. Endotoxin is reported against its limit, sterility as growth or no growth, and heavy metals as a screen for arsenic, cadmium, lead, mercury.

Verify a batch yourself

Every certificate carries a Kovera Labs report number and access code, both published above. Enter them at koveralabs.com/verify and the laboratory returns its own copy of the record. Vials ship unlabeled, so the batch number for your order is on the certificate supplied with your shipment.

FREQUENTLY ASKED

4 ITEMS
Does BPC-157 come with a certificate of analysis?

Yes. 2 batches of BPC-157 have a published certificate, covering the 5 mg and 10 mg fills. The 20 mg fill does not have a published certificate yet; the certificate for each batch ships with the order.

What purity is BPC-157 tested to?

The published batches were tested by reverse-phase HPLC against a purity specification of more than 98%. They returned 99.384%–99.446%, reported at the precision the laboratory issued.

Who tests BPC-157?

Kovera Labs, a third-party laboratory. Every certificate carries a Kovera Labs report number, and each batch is tested for purity, identity by LC-MS, net content, endotoxin, sterility, and heavy metals.

How do I verify a BPC-157 certificate?

Enter the report number and access code printed on the certificate at koveralabs.com/verify. Both are published for every batch on this page. Vials ship unlabeled, so an order's batch number is on the certificate that ships with it.

BPC-157, on the record.

2 BATCHES PUBLISHED · SIX-PANEL TESTED · SAME-DAY FROM SOUTHERN CALIFORNIA

Order BPC-157