| FILL | BATCH | PURITY | IDENTITY | ENDOTOXIN | STERILITY | CERTIFIED |
|---|---|---|---|---|---|---|
| 5 MG | BATCH-5014 | 99.384% | BPC-157 · confirmed | Pass | No Growth | 2026-08-04 |
| 10 MG | BATCH-10765 | 99.446% | BPC-157 · confirmed | Pass | No Growth | 2026-08-04 |
| 20 MG | Batch-BC20001 | 99.716% | BPC-157 · confirmed | Pass | No Growth | 2026-10-15 |
BPC-157 5 MG · BATCH-5014
99.384% PURITY- PURITY
- 99.384% against a specification of > 98%
- NET CONTENT
- 5.41 mg (fill 5 MG)
- IDENTITY
- BPC-157, confirmed by LC-MS
- ENDOTOXIN
- Pass · limit ≤ 0.5 EU/mL
- STERILITY
- No Growth
- HEAVY METALS
- Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
- REPORT · ACCESS CODE
- KVR-2026-DFBC79-S460 · AJ8QR71

BPC-157 10 MG · BATCH-10765
99.446% PURITY- PURITY
- 99.446% against a specification of > 98%
- NET CONTENT
- 11.06 mg (fill 10 MG)
- IDENTITY
- BPC-157, confirmed by LC-MS
- ENDOTOXIN
- Pass · limit ≤ 0.5 EU/mL
- STERILITY
- No Growth
- HEAVY METALS
- Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
- REPORT · ACCESS CODE
- KVR-2026-BB76EF-S461 · 2M3Q0I2

BPC-157 20 MG · Batch-BC20001
99.716% PURITY- PURITY
- 99.716% against a specification of > 98%
- NET CONTENT
- 20.72 mg (fill 20 MG)
- IDENTITY
- BPC-157, confirmed by LC-MS
- ENDOTOXIN
- Pass · limit ≤ 0.5 EU/mL
- STERILITY
- No Growth
- HEAVY METALS
- Screen negative
- FENTANYL
- Not Detected
- REPORT · ACCESS CODE
- KVR-2026-388A9E · 08QAZ6L

Reading a BPC-157 certificate
Purity is measured by reverse-phase HPLC on a C18 column with detection at 214 nm — the trace shown under each batch above. The figure is the share of the signal in the BPC-157 peak, and it is reported against the specification printed beside it.
Identity is confirmed separately by LC-MS, which checks the mass of what is in the vial against what is expected for BPC-157. Purity without identity would say how clean the sample is, not what it is.
Net content is the measured quantity in the vial against its stated fill. Endotoxin is reported against its limit, sterility as growth or no growth, and heavy metals as a screen for arsenic, cadmium, lead, mercury. Newer certificates also screen for fentanyl.
Verify a batch yourself
Every certificate carries the lab’s report number and access code, both published above. Enter them on the lab’s verification page and the laboratory returns its own copy of the record. Vials ship unlabeled, so the batch number for your order is on your invoice.
FREQUENTLY ASKED
4 ITEMSDoes BPC-157 come with a certificate of analysis?
Yes. 3 batches of BPC-157 have a published certificate, covering the 5 mg fill (BATCH-5014), the 10 mg fill (BATCH-10765) and the 20 mg fill (Batch-BC20001). Every fill currently in the catalog is covered. BPC-157 is sold wholesale in 10-vial kits from $9.00 per vial, with per-tier pricing on the BPC-157 product page.
What purity is BPC-157 tested to?
The published batches were tested by reverse-phase HPLC against a purity specification of more than 98%. They returned 99.384%–99.716%, reported at the precision the laboratory issued.
Who tests BPC-157?
An independent third-party laboratory. The 3 published batches of BPC-157 (BATCH-5014, 5 mg, BATCH-10765, 10 mg and Batch-BC20001, 20 mg) were certified August 4, 2026 and October 15, 2026, each tested for purity, identity by LC-MS, net content, endotoxin, sterility, and heavy metals, with the lab's report number on the certificate.
How do I verify a BPC-157 certificate?
Enter the report number and access code printed on the certificate on the lab's verification page, linked from this page. Both are published here for batches BATCH-5014, BATCH-10765 and Batch-BC20001. Vials ship unlabeled, so an order's batch number is on its invoice.
BPC-157, on the record.
3 BATCHES PUBLISHED · SIX-PANEL TESTED · SAME-DAY FROM SOUTHERN CALIFORNIA
Order BPC-157 →