PEPTIDE WHOLESALERS
CATALOG · NAD+ · CERTIFICATES

NAD+ Certificate of Analysis

2 batches of NAD+, each tested by Kovera Labs for purity, identity, net content, endotoxin, sterility, and heavy metals. Every result below is copied from the laboratory’s certificate, at the precision it was issued.

BATCHES PUBLISHED2
PURITY RETURNED99.294%–99.516%
FILLS COVERED500 MG, 1000 MG
LATEST CERTIFIED2026-08-04
FILLBATCHPURITYIDENTITYENDOTOXINSTERILITYCERTIFIED
500 MGBATCH-5002199.294%NAD+ Buffered · confirmedPassNo Growth2026-08-04
1000 MGBATCH-1000799.516%NAD+ Buffered · confirmedPassNo Growth2026-08-04

NAD+ 500 MG · BATCH-50021

99.294% PURITY
PURITY
99.294% against a specification of > 98%
NET CONTENT
479.26 mg (fill 500 MG)
IDENTITY
NAD+ Buffered, confirmed by LC-MS
ENDOTOXIN
Pass · limit ≤ 0.5 EU/mL
STERILITY
No Growth
HEAVY METALS
Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
REPORT · ACCESS CODE
KVR-2026-0DB6CA-S483 · JMPOV53
CHROMATOGRAM · RP-HPLC · C18 · DAD @ 214 nm
HPLC chromatogram for NAD+ 500 MG, batch BATCH-50021

NAD+ 1000 MG · BATCH-10007

99.516% PURITY
PURITY
99.516% against a specification of > 98%
NET CONTENT
994.82 mg (fill 1000 MG)
IDENTITY
NAD+ Buffered, confirmed by LC-MS
ENDOTOXIN
Pass · limit ≤ 0.5 EU/mL
STERILITY
No Growth
HEAVY METALS
Arsenic Negative · Cadmium Negative · Lead Negative · Mercury Negative
REPORT · ACCESS CODE
KVR-2026-2EDC4F-S484 · 5302R1R
CHROMATOGRAM · RP-HPLC · C18 · DAD @ 214 nm
HPLC chromatogram for NAD+ 1000 MG, batch BATCH-10007

Reading a NAD+ certificate

Purity is measured by reverse-phase HPLC on a C18 column with detection at 214 nm — the trace shown under each batch above. The figure is the share of the signal in the NAD+ peak, and it is reported against the specification printed beside it.

Identity is confirmed separately by LC-MS, which checks the mass of what is in the vial against what is expected for NAD+. Purity without identity would say how clean the sample is, not what it is.

Net content is the measured quantity in the vial against its stated fill. Endotoxin is reported against its limit, sterility as growth or no growth, and heavy metals as a screen for arsenic, cadmium, lead, mercury.

Verify a batch yourself

Every certificate carries a Kovera Labs report number and access code, both published above. Enter them at koveralabs.com/verify and the laboratory returns its own copy of the record. Vials ship unlabeled, so the batch number for your order is on the certificate supplied with your shipment.

FREQUENTLY ASKED

4 ITEMS
Does NAD+ come with a certificate of analysis?

Yes. 2 batches of NAD+ have a published certificate, covering the 500 mg and 1000 mg fills. Every fill currently in the catalog is covered.

What purity is NAD+ tested to?

The published batches were tested by reverse-phase HPLC against a purity specification of more than 98%. They returned 99.294%–99.516%, reported at the precision the laboratory issued.

Who tests NAD+?

Kovera Labs, a third-party laboratory. Every certificate carries a Kovera Labs report number, and each batch is tested for purity, identity by LC-MS, net content, endotoxin, sterility, and heavy metals.

How do I verify a NAD+ certificate?

Enter the report number and access code printed on the certificate at koveralabs.com/verify. Both are published for every batch on this page. Vials ship unlabeled, so an order's batch number is on the certificate that ships with it.

NAD+, on the record.

2 BATCHES PUBLISHED · SIX-PANEL TESTED · SAME-DAY FROM SOUTHERN CALIFORNIA

Order NAD+